b'1.8.5 INSTALLATIONOnce the wall has been battened out as per cavity construction details, Weathertexs product specific standard fixing instructions shall be followed to install the cladding on to the frame. Step 1:Install suitable membrane (See wall sarking requirements section 1.4.7)Step 2:Install Cavity Closer & Primelok starter strip (if required).The bottom edge of the starter strip must not be above the bottom edge of the cavity closer.Step 3:Install Thermal Break battens as per cavity construction detailsStep 4:Ensure requiredInstall Weathertex as per ground clearancestandard instructionsis maintained(Refer to general requirements section 1.4.4)20mm Pine 12mm Thermal PolystyreneBreak ThermalBreakPrimelokPrimelokPrimelok Starter StripLarge Cavity Large Cavity Closer Closer20mm Pine 12mm PolystyreneThermal Break Primelok Thermal Break PrimelokWeathertex 15'